HP GbE2 Switch Blade

As with many Data Centers we've been deploying a large number of blade servers and switches. We're primarily an HP shop from a server,desktop and laptop perspective and we've been working with HP Blade System for the past two years.

HP actually OEM's two different GbE2 switches for their Blade enclosures. One is based off a Nortel (Alteon) solution and the other is based off a Cisco solution. We're using the Nortel version and we'll be focusing on that hardware in this post. If your unfamiliar with the Alteon CLI your going to need a few minutes to catch on. It's pretty simple but very different from either the Nortel CLI or the Cisco CLI. Another important point is that the enclosure can actually accommodate two HP GbE2 switches. There's an "A" side and a "B" side. You only need an "A" side switch to provide connectivity for the servers that will be housed in the enclosure but for high-availability solutions you'll definitely need two switches installed into the enclosure.

In the following post I'll outline how to configure a HP GbE2 Switch Blade trunking both ports into a MultiLink trunk. We'll only using one HP GbE2 switch for this example and ignore the "B" switch. You should console up to the HP GbE2 using a serial cable (straight thru cable 9600, 8, N 1). The default password is “admin”.

[Main Menu]
Jul 19 8:07:04 NOTICE mgmt: admin login from host 10.101.20.1
info - Information Menu
stats - Statistics Menu
cfg - Configuration Menu
oper - Operations Command Menu
boot - Boot Options Menu
maint - Maintenance Menu
diff - Show pending config changes [global command]
apply - Apply pending config changes [global command]
save - Save updated config to FLASH [global command]
revert - Revert pending or applied changes [global command]
exit - Exit [global command, always available]

>> Main#
Set Admin password
We'll start out by setting the administrator password on the switch.
>> Main# /cfg/sys/access/user/admpw 
Changing ADMINISTRATOR password; validation required:

Enter current admin password:

Enter new administrator password:

Re-enter new administrator password:

New administrator password accepted.
Set IP Address
Next we'll setup an IP address on one of the interfaces.
>> Main# cfg/l3/if 1

[IP Interface 1 Menu]
addr - Set IP address
mask - Set subnet mask
vlan - Set VLAN number
relay - Enable/disable BOOTP relay
ena - Enable IP interface
dis - Disable IP interface
del - Delete IP interface
cur - Display current interface configuration

>> IP Interface 1#>> addr 10.101.255.118
Current IP address: 0.0.0.0
New pending IP address: 10.101.255.118
Pending new subnet mask: 255.0.0.0

>> IP Interface 1# mask 255.255.255.0
Current subnet mask: 0.0.0.0
New pending subnet mask: 255.255.255.0

>> IP Interface 1# vlan 200
Current VLAN: 1
New pending VLAN: 200

>> IP Interface 1# ena
Current status: disabled New status: enabled
Set IP Default Gateway
Next we'll setup a default gateway for the switch.
>> Main# cfg/l3/gw 1
[Default gateway 1 Menu]
addr - Set IP address
intr - Set interval between ping attempts
retry - Set number of failed attempts to declare gateway DOWN
arp - Enable/disable ARP only health checks
ena - Enable default gateway
dis - Disable default gateway
del - Delete default gateway
cur - Display current default gateway configuration

>> Default gateway 1# addr 10.101.255.1
Current IP address: 0.0.0.0
New pending IP address: 10.101.255.1

>> Default gateway 1# ena
Current status: disabled
New status: enabled
Create Trunk Interface
We'll create a Multilink trunk interface (Etherchannel) utilizing ports 19 and 20. Switch ports 19-22 are GBIC interfaces which are populated by 1000BaseSX SFPs.
>> Main# /cfg/l2/trunk 1
[Trunk group 2 Menu]
add - Add port to trunk group
rem - Remove port from trunk group
ena - Enable trunk group
dis - Disable trunk group
del - Delete trunk group
cur - Display current Trunk Group configuration

>> Trunk group 2# add 19
Port 19 added.
>> Trunk group 2# add 20
Port 20 added.
>> Trunk group 2# ena
Current status: disabled
New status: enabled
Enable 802.1q (tagging) on fiber uplinks
The external uplinks are ports 19 and 20. The internal crossconnect links between the two HP GbE2 switches are on ports 17 and 18. We need to enable 802.1q VLAN tagging on the uplink ports so we can bridge multiple VLANs across the uplinks.
>> Main# /cfg/port 17
------------------------------------------------------------
[Port 19 Menu]
gig - Gig Phy Menu
aclqos - Acl/Qos Configuration Menu
8021ppri - Set default 802.1p priority
pvid - Set default port VLAN id
name - Set port name
rmon - Enable/Disable RMON for port
tag - Enable/disable VLAN tagging for port
tagpvid - Enable/disable tagging on pvid
brate - Set BroadCast Threshold
mrate - Set MultiCast Threshold
drate - Set Dest. Lookup Fail Threshold
ena - Enable port
dis - Disable port
cur - Display current port configuration
>> Port 17# tag e
Current VLAN tag support: disabled
New VLAN tag support: enabled
Port 17 changed to tagged.
I’m going to just provide the commands for the remaining ports and skip showing the enter text of the menu to help save on the length of this document.
>> Port 17# /cfg/port 18/tag e
Current VLAN tag support: disabled
New VLAN tag support: enabled
Port 18 changed to tagged.
>> Port 19# /cfg/port 19/tag e
Current VLAN tag support: disabled
New VLAN tag support: enabled
Port 19 changed to tagged.
>> Port 19# /cfg/port 20/tag e
Current VLAN tag support: disabled
New VLAN tag support: enabled
Port 20 changed to tagged.
Create VLAN 200 for management of the switch itself.
>> Main# /cfg/l2/vlan 200
VLAN number 200 with name "VLAN 200" created.
------------------------------------------------------------
[VLAN 200 Menu]
name - Set VLAN name
stg - Assign VLAN to a Spanning Tree Group
add - Add port to VLAN
rem - Remove port from VLAN
def - Define VLAN as list of ports
ena - Enable VLAN
dis - Disable VLAN
del - Delete VLAN
cur - Display current VLAN configuration

>> VLAN 200# name "10-101-255-0/24”
Current VLAN name:
New VLAN name: 10-101-255-0/24
>> VLAN 200# add 17
Current ports for VLAN 200: empty Pending new ports for VLAN 200: 17
>> VLAN 200# add 18
Current ports for VLAN 200: empty Pending new ports for VLAN 200: 17-18
>> VLAN 200# add 19
Current ports for VLAN 200: empty Pending new ports for VLAN 200: 17-19
>> VLAN 200# add 20
Current ports for VLAN 200: empty Pending new ports for VLAN 200: 17-20
Spanning Tree Protocol (Disable STP on trunk uplinks)
>> Main# /cfg/l2/stp 1
------------------------------------------------------------
[Spanning Tree Group 1 Menu]
brg - Bridge parameter menu
port - Port parameter menu
add - Add VLAN(s) to Spanning Tree Group
remove - Remove VLAN(s) from Spanning Tree Group
clear - Remove all VLANs from Spanning Tree Group
on - Globally turn Spanning Tree ON
off - Globally turn Spanning Tree OFF
default - Default Spanning Tree and Member parameters
cur - Display current bridge parameters

>> Spanning Tree Group 1# port 19
------------------------------------------------------------
[Spanning Tree Port 19 Menu]
prior - Set port Priority (0-255)
cost - Set port Path Cost (1-65535 (802.1d) / 1-200000000 (MSTP/RSTP) / 0 for auto)
link - Set port link type (auto, p2p, or shared; default: auto)
edge - Enable/disable edge port
fastfwd - Enable/disable Port Fast Forwarding mode
on - Turn port's Spanning Tree ON
off - Turn port's Spanning Tree OFF
cur - Display current port Spanning Tree parameters
>> Spanning Tree Port 19# off
Current Port 19 Spanning Tree setting: ON
New Port 19 Spanning Tree setting: OFF
>> Main# /cfg/l2/stp 1/port 20/off
Current Port 20 Spanning Tree setting: ON
New Port 20 Spanning Tree setting: OFF
Network Time Protocol
>> Main# /cfg/sys/ntp
----------------------------------------------------------
[NTP Server Menu]
prisrv - Set primary NTP server address
secsrv - Set secondary NTP server address
intrval - Set NTP server resync interval
tzone - Set NTP timezone offset from GMT
dlight - Enable/Disable daylight savings time
on - Turn NTP service ON
off - Turn NTP service OFF
cur - Display current NTP configuration
>> NTP Server# prisrv 10.101.20.1
Current NTP server address: 0.0.0.0 Enter new NTP server address: 10.101.20.1
>> NTP Server# secsrv 10.111.20.1
Current NTP server address: 0.0.0.0 Enter new NTP server address: 10.111.20.1
>> NTP Server# tzone -5:00
Current GMT timezone offset: -8:00
Enter new GMT timezone offset in hours [-12:00, +12:00]: -5:00
>> NTP Server# on
Current status: OFF
New status: ON
>> NTP Server# dlight e
Current status: disabled
New status: enable
Set PVID on Uplink Ports
>> Main# /cfg/port 17/pvid 200
>> Main#
/cfg/port 18/pvid 200
>> Main#
/cfg/port 19/pvid 200
>> Main#
/cfg/port 20/pvid 200
pre>
Remove VLAN 1 from Uplink Ports
>> Layer 2# vlan 1 
------------------------------------------------------------
[VLAN 1 Menu]
name - Set VLAN name
stg - Assign VLAN to a Spanning Tree Group
add - Add port to VLAN
rem - Remove port from VLAN
def - Define VLAN as list of ports
ena - Enable VLAN dis - Disable VLAN
del - Delete VLAN
cur - Display current VLAN configuration
>> VLAN 1#
rem 17
Current ports for VLAN 1: 1-18 21-24
Pending new ports for VLAN 1: 1-16 18 21-24
>> VLAN 1#
rem 18
Current ports for VLAN 1: 1-18 21-24
Pending new ports for VLAN 1: 1-16 21-24
>> VLAN 1#
rem 19
Current ports for VLAN 1: 1-18 21-24
Pending new ports for VLAN 1: 1-16 21-24
>> VLAN 1#
rem 20
Current ports for VLAN 1: 1-18 21-24
Pending new ports for VLAN 1: 1-16 21-24

Simple Network Management Protocol (SNMP)


>> Main# /cfg/sys/ssnmp/name swA-hpenc06-rack44.acme.org
Current SNMP "sysName": ""
Pending new "sysName": "swA-hpenc06-rack44.mdc.mlhs.org"

>> Main# /cfg/sys/ssnmp/rcomm readonly
Current SNMP read community string: "public"
Pending new read community string: "readonly"

>> Main# /cfg/sys/ssnmp/wcomm readwrite
Current SNMP write community string: "private"
Pending new write community string: "readwrite"

>> Main# /cfg/sys/ssnmp/auth dis
Current SNMP "sysAuthenTrap" setting: disabled
New SNMP "sysAuthenTrap" setting: disabled

Disable BOOTP

>> Main# /cfg/sys/bootp d
Warning: Enabling bootp will overwrite IP interface 1 and
IP gateway 1's configurations.

Current BOOTP: enabled
New BOOTP: disabled

Save Configuration & Apply Configuration
The most important part of this exercise is apply the changes we've made and saving the configuration. Unlike Cisco or even Nortel switches the changes we've made above don't take affect until they are 'applied' to the switch with the "apply" command.

>> System# apply
------------------------------------------------------------------
Apply complete; don't forget to "save" updated configuration.

>> Jul 19 13:26:12 INFO mgmt: new configuration applied
System# save
Request will first copy the FLASH "active" config to "backup",
then overlay FLASH "active" with new config.
Confirm saving to FLASH [y/n]: y
New config successfully saved to FLASH.

>>
Jul 19 13:26:19 INFO mgmt: new configuration saved
Hopefully that will give you a good idea of how to configure an HP GbE2 switch in a basic configuration.

Cheers!

No comments: